Customization: | Available |
---|---|
Install: | Horizontal |
Medium Temperature: | Cold Water |
Still deciding? Get samples of US$ 6/Piece
Request Sample
|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Volumetric Piston Horizontal Type
Material body: Nylon Plastic
Size: DN15 (1/2" ), Available for cold water(40°C)
Accuracy: Class C/ R160/ R200
Easy for interchange & maintenance
MAIN TECHNICAL DATA According to ISO4064 (GB/T778.1-1996) Standard
Meter size Dia DN (mm) |
Class | qs Overload Flow |
qs Nominal Flow |
qs Transitional Flow |
Qmin Min Flow |
Min Reading Lectura |
Max Reading Lectura |
m3/h | L/h | m3 | |||||
15 | C | 3 | 1.5 | 22.5 | 15 | 0.0001 | 99999 |
MAIN TECHNICAL DATA According to ISO4064 (GB/T778.1-2007) Standard
DN SIZE |
Mm Inch |
15 1/2" |
Q4(m³/h) | 3.125 | |
Q3(m³/h) | 2.5 | |
R160 | Q2(L/h) | 25 |
Q1(L/h) | 15.625 | |
R200 | Q2(L/h) | 20 |
Q1(L/h) | 12.5 | |
Min reading(m³) | 0.0001 | |
Max reading(m³) | 99,999 | |
Max pressure(MAP) | 16 | |
Max loss(ΔP) | 63 | |
Max temperature | T50 | |
Pulse output option | Vmax=24V, Imax=100mA, Pmax=2W |
INDICATING ERROR
At low zone is ±5% from minimum flow rate (qmin) to transitional flow rate (qt) exclusive boundary
At high zone is ±2% from transitional flow rate (qt) to overload flow rate (qs)
DIMENSIONS AND WEIGHT
Meter size Dia DN (mm) |
L Length |
B Width |
H Height |
Connrcting Thread D |
Weight Kg |
||
mm | |||||||
15 | 165 | 99 | 104 | G 3/4B | 0.65 |
WORKING CONDITION
Water temperature:≤40ºC for cold water meter