After-sales Service: | 5 Years |
---|---|
Warranty: | 5 Years |
Install: | Horizontal |
Model no. | Nominal diameter DN(mm) | Turndown ratio | Overload flow Q4 | Permanent flow Q3 |
Transitional flow Q2 | Min flow Q1 |
M3/h | ||||||
LXSGK-15 | 15 | R80 | 3.125 | 2.5 | 0.05 | 0.03125 |
LXSGK-20 | 20 | R80 | 5.0 | 4.0 | 0.08 | 0.05 |
LXSGK-25 | 25 | R80 | 7.875 | 6.3 | 0.126 | 0.07875 |
2) If the temperature≤30ºC, in the upper zone from Q2 inclusive up to and including Q4 is ±2%
3) If the temperature>30ºC, in the upper zone from Q2 inclusive up to and including Q4 is ±3%
Note: Technical data conform to ISO4064 standard
Electrical Technical Data for RF Card Water Meter
Working current |
Low
voltage
protection
|
Quiescent current |
Battery
voltage
|
Nominal
Pressure
|
water volume
per 1 pulse
signal
|
<20mA | 2.8V | <15uA | 3.6V | 3.0V~3.6V | 100L |
3.Working conditions:
Water temperature
≤50ºC for cold water meter
≤90ºC for hot water meter
Working pressure: ≤16bar
Relative humidity: ≤90%
Size |
Length
L
|
Length
L1
|
Width
B
|
Height
H
|
Connecting Thread | |
mm | ||||||
15 | 165 | 259 | 86 | 117 | G3/4B | R1/2 |
20 | 195 | 299 | 86 | 117 | G1B | R3/4 |
25 | 225 | 345 | 86 | 117 | G1 1/4B | R1 |